Dual Wall Shut-off Valve Pricelist

Takaitaccen Bayani:

Vacuum Insulated Shut-off Valve shine ke da alhakin sarrafa buɗewa da rufewar Bututun Insulated Vacuum. Haɗin kai tare da wasu samfuran jerin bawul ɗin VI don cimma ƙarin ayyuka.

Take: Dual Wall Shut-off Valve Pricelist


Cikakken Bayani

Tags samfurin

Takaitaccen bayanin samfur:

  • Babban Inganci: Bawul ɗin rufewar bangon mu biyu ana kera su da kayan inganci masu inganci, suna tabbatar da dorewa da aminci.
  • Daidaitaccen Aiki: Kowane bawul an ƙera shi tare da daidaitaccen kashewa da sarrafa kwarara.
  • Aikace-aikacen da yawa: Bawul ɗin sun dace da aikace-aikacen masana'antu da kasuwanci daban-daban, suna ba da mafita mai sauƙi don buƙatu daban-daban.
  • Farashin Gasa: Muna ba da farashin gasa ga Valves ɗin mu na Katanga na Dual Shut-off, yana mai da su zaɓi mai inganci don kasuwanci.

Cikakken Bayanin Samfura: Maɗaukakin Kayan Aiki: Ƙaƙƙarfan Katangar Mu Dual Rufe-kashe Valves ana yin su ta amfani da kayan ƙima don jure yanayin aiki mai ƙarfi. Gina bangon bangon dual yana haɓaka ƙarfi da tsawon rayuwar bawuloli, yana tabbatar da cewa zasu iya jure yanayin masana'antu masu buƙata.

Injiniyan Madaidaici: Kowane bawul ɗin yana yin aikin injiniya sosai don ba da tabbacin aiki daidai. Ƙirar tana ba da izinin rufewa mai santsi da sarrafa ruwa ko iskar gas, rage haɗarin ɗigowa da kuma tabbatar da kyakkyawan aiki.

Aikace-aikace iri-iri: Waɗannan bawuloli sun dace da aikace-aikace daban-daban, gami da masana'antu masana'antu, mai da gas, kula da ruwa, da ƙari. Ƙwararren su ya sa su zama abin dogara ga masana'antu daban-daban, suna ba da haɗin kai a cikin tsarin daban-daban.

Farashin Gasa: Mun fahimci mahimmancin ingancin farashi ga kasuwanci. Don haka, Valves ɗinmu na Dual Shut-off ana siyar da farashi mai gasa ba tare da yin la'akari da inganci ba. Wannan yana tabbatar da cewa abokan cinikinmu sun sami ƙima na musamman don saka hannun jari.

A ƙarshe, Valves ɗinmu na Dual Shut-off Valves yana ba da ingantacciyar inganci, ingantaccen aiki, juzu'i, da farashi mai gasa. A matsayin babban masana'anta, mun himmatu don samar da ingantaccen mafita waɗanda ke biyan bukatun abokan cinikinmu a cikin masana'antu daban-daban.

Tare da ingantattun hanyoyin samar da mu da kuma sadaukar da kai ga nagarta, muna tabbatar da cewa Dual Wall Shut-off Valves mu manne da mafi girman ma'auni, yana ba da aiki da dorewa waɗanda kasuwancin za su iya dogaro da su.

Aikace-aikacen samfur

Jerin samfurin Vacuum Valve, Vacuum Pipe, Vacuum Hose da Mai Rarraba Mataki a cikin Kamfanin Kayan Aikin HL Cryogenic, wanda ya wuce ta jerin manyan jiyya na fasaha, ana amfani dashi don canja wurin oxygen na ruwa, nitrogen ruwa, argon ruwa, hydrogen ruwa, ruwa. helium, LEG da LNG, kuma ana ba da waɗannan samfuran don kayan aikin cryogenic (misali tankuna na cryogenic, dewars da akwatin sanyi da sauransu) a cikin masana'antar rabuwar iska, gas, jirgin sama, lantarki, superconductor, chips, kantin magani, bankin biobank, abinci & abin sha, sarrafa kansa. taro, injiniyan sinadarai, ƙarfe & ƙarfe, da binciken kimiyya da sauransu.

Bawul mai Insulated Shut-off Valve

Vacuum Insulated Shut-off/Stop Valve, wato Vacuum Jacketed Shut-off Valve, shine mafi yawan amfani da jerin bawul na VI a cikin VI Piping da VI Hose System. Ita ce ke da alhakin sarrafa budewa da rufe manyan bututun mai da reshe. Haɗin kai tare da wasu samfuran jerin bawul ɗin VI don cimma ƙarin ayyuka.

A cikin tsarin bututun da aka saka jaket, mafi yawan asarar sanyi shine daga bawul ɗin cryogenic akan bututun. Saboda babu injin insulation sai dai rufin al'ada, ƙarfin asarar sanyi na bawul ɗin cryogenic ya fi na bututun da aka yi jaki na ɗimbin mita. Don haka akwai sau da yawa abokan ciniki waɗanda suka zaɓi bututun da aka yi amfani da su, amma bawuloli na cryogenic a ƙarshen bututun bututun sun zaɓi rufin al'ada, wanda har yanzu yana haifar da hasara mai yawa na sanyi.

VI Shut-off Valve, a sauƙaƙe, ana sanya jaket ɗin injin a kan bawul ɗin cryogenic, kuma tare da tsarin sa na fasaha yana samun mafi ƙarancin asarar sanyi. A cikin masana'antun masana'antu, VI Shut-off Valve da VI Pipe ko Hose an riga an tsara su a cikin bututun guda ɗaya, kuma babu buƙatar shigarwa da jiyya a wurin. Don kulawa, ana iya maye gurbin sashin hatimi na VI Shut-off Valve cikin sauƙi ba tare da lalata ɗakin ɗakin sa ba.

VI Shut-off Valve yana da nau'ikan masu haɗawa da haɗin kai don saduwa da yanayi daban-daban. A lokaci guda, ana iya daidaita mai haɗawa da haɗin kai bisa ga buƙatun abokin ciniki.

HL tana karɓar alamar bawul ɗin cryogenic wanda abokan ciniki suka zayyana, sannan kuma ya sanya bawul ɗin da aka keɓe ta HL. Wasu samfura da samfuran bawuloli ƙila ba za a iya sanya su su zama bawul ɗin da aka keɓe ba.

Game da jerin bawul ɗin VI ƙarin cikakkun bayanai da tambayoyi na keɓaɓɓu, da fatan za a tuntuɓi kayan aikin HL cryogenic kai tsaye, za mu bauta muku da zuciya ɗaya!

Bayanin Siga

Samfura Saukewa: HLVS000
Suna Bawul mai Insulated Shut-off Valve
Diamita na Suna DN15 ~ DN150 (1/2" ~ 6")
Tsananin Tsara ≤64bar (6.4MPa)
Zazzabi Zane -196 ℃ ~ 60 ℃ (LH2& LHe: -270 ℃ ~ 60 ℃)
Matsakaici LN2, LOX, LAr, LHe, LH2, LNG
Kayan abu Bakin Karfe 304/304L/316/316L
Shigar da kan-site No
Jiyya mara kyau a wurin No

HLVS000 Jerin,000yana wakiltar diamita mara kyau, kamar 025 shine DN25 1" kuma 100 shine DN100 4".


  • Na baya:
  • Na gaba:

  • Bar Saƙonku